Document verification

How to check an EICR or safety certificate is genuine

Written for landlords, letting and managing agents, and insurers holding a PDF they did not produce. The honest answer first: there is no national database of electrical reports in the UK, so nobody can look one up for you. Here is what you can check instead.

Last reviewed 6 August 2026

What a QR code proves, and what it does not

Every document issued through TradeBooked carries a QR code and a private verification link. Scanning it opens the record the issuing business created. That is a genuinely useful thing, and it is a much smaller thing than the word verified usually suggests, so it is worth being blunt about the boundary.

It does prove

  • The document exists in the TradeBooked register, and which business issued it.
  • What that business actually recorded: the reference number, the dates, the property. Compare them against the copy in your hand, because a PDF edited in any of those places will not match.
  • Whether the document is still the current one, or has been superseded by a newer version.
  • That the document was issued rather than left as an unfinished draft.

It does not prove

  • That the person who signed it is competent, or registered with the scheme they named.
  • That the readings, the observations or the overall assessment are correct.
  • That the inspection happened at all, or was carried out properly.
  • That the installation is safe.

A verification link tells you a document is the one that was issued. It cannot tell you the work behind it was any good. If a platform implies its QR code makes a certificate verified in the sense of verified as correct, it is overselling, and we are not going to do that here.

How to check a TradeBooked document

Holding the document?

Scan the QR code printed on it with your phone camera. If you were sent the PDF rather than a paper copy, the QR code and the caption beneath it are both links, so you can tap either instead. There is no search box on this page, and there is not one anywhere else on the site either.

The page the link opens shows you, and only shows you:

  • what kind of document it is, and its reference number
  • the business that issued it, and the date they issued it
  • the inspection date
  • the next due date, where that type of document renews at all
  • the property, masked to the first line of the address and the outward half of the postcode
  • a short document fingerprint
  • a clear warning if a newer version has replaced it, with the reference number of the replacement

You will not see the PDF, the readings, the schedules, the occupier, or anyone’s contact details. A draft that was never issued resolves to nothing at all, so an unfinished document can never be made to read as genuine. For the full report, ask the business that issued it.

Why there is no lookup by number or address

Because verification is proof of possession. The only key that works is the unguessable token inside the document’s own QR code. A search by certificate number or by address would let anyone walk a street, or count upwards through reference numbers, and read other people’s compliance records. That is a worse outcome than the mild inconvenience of needing the document in front of you.

What TradeBooked documents you might be handed

Electricians using TradeBooked can produce an Electrical Installation Condition Report (EICR), a Minor Electrical Installation Works Certificate and an EV charge point installation record, plus a PAT testing record. Security engineers can produce the minor works certificate only.

What a genuine EICR shows, whoever produced it

An EICR follows a model form published with the wiring regulations, so real reports look broadly alike whichever software or paper pad produced them. Whatever the layout, the following should all be there and filled in.

  • Who inspected. The inspector’s name and position, and the business they inspected for. On a larger job the person who authorised the report for issue is named too.
  • Their scheme and registration number. A competent person scheme (NICEIC, NAPIT and others) plus the number itself. Older reports may name ELECSA or Stroma, brands since folded into NICEIC and NAPIT. A blank here is the single biggest red flag on the page.
  • Why the report was produced, and what was inspected: the extent of the inspection, any limitations agreed beforehand, and who they were agreed with. Limitations are normal. Silence about them is not.
  • The supply and earthing details at the origin: earthing arrangement, external loop impedance Ze, prospective fault current, main switch and bonding.
  • A schedule of inspection, item by item, with an outcome against each.
  • A schedule of test results, circuit by circuit, with actual measured numbers: continuity, insulation resistance, polarity, earth fault loop impedance Zs, RCD disconnection times. A report with no readings is not an EICR, whatever it says at the top.
  • Observations, each carrying a classification code and pointing back to the schedule item it came from. If there are none, the report should positively state that no remedial action is required, rather than simply leaving the section empty.
  • An overall assessment, satisfactory or unsatisfactory, that agrees with the codes below it.
  • A date for the next inspection, with the inspector’s reason for choosing that interval.
  • A signature. An unsigned report is a draft.

The codes: C1, C2, C3 and FI

Every observation on an EICR carries one of four classification codes. They are the fastest way to read a report you did not commission.

C1Danger presentMakes the report unsatisfactory

Risk of injury. Immediate remedial action is necessary. A competent electrician should have made it safe before leaving, and the report should say whether they did.

C2Potentially dangerousMakes the report unsatisfactory

Not dangerous today, but it could become so. Urgent remedial action is necessary.

C3Improvement recommendedAdvisory, does not affect the result

The installation is not dangerous and complies with an older edition of the wiring regulations, but it could be better. Advisory only.

FIFurther investigation advisedAdvisory, does not affect the result

The inspector could not get far enough to reach a conclusion and advises a closer look. Advisory only.

The rule most websites still get wrong

Under BS 7671:2018+A4:2026, whose model forms were published in April 2026, only a C1 or a C2 makes the overall assessment unsatisfactory. C3 and FI are advisory and do not affect it. Under the older A2:2022 form an FI forced an unsatisfactory result too, and a great many pages online still describe that older rule as though it were current. If you are reading a report produced before the change, it is on the older form rather than wrong. If the codes and the assessment on a recent report do not line up, that is a fair question to put to the inspector.

There is no national database of EICRs in the UK

This is the part people arrive looking for, so it deserves saying plainly. There is no public register of Electrical Installation Condition Reports, no central archive, and no way to type in an address or a certificate number and see whether a report exists. Nothing you can do online will produce one.

The reason is structural rather than an oversight. New electrical work in a home in England and Wales is notifiable under Part P of the building regulations, and a registered electrician notifies it through their scheme, which is why a building regulations compliance certificate for that work can be requested again later. A condition report is not new work. It is an inspection of what is already there, so it is not notified to anyone, and there is no public register or council file you can request it from. The only complete copies are the inspector’s own records and the one you were given.

So the practical check is not the report. It is the person who signed it.

How to check the electrician independently

Take the scheme name and registration number off the report and look them up yourself. The registers below are free to search. The last link is an independent charity rather than a register, and it is the one to read if you are not sure what to do next.

  • Registered Competent Person Electrical

    One search across every government authorised scheme, covering electricians registered to work in homes in England and Wales. Start here if you do not know which scheme the electrician is with.

  • NICEIC

    Search for the business by name, postcode or registration number. ELECSA registrations were moved across when that brand was retired, so an ELECSA number on an older report is checked here.

  • NAPIT

    Find an installer, and check what work their registration actually covers. The Stroma installer scheme merged into NAPIT in 2021, so a Stroma number is checked here too.

  • Electrical Safety First

    Independent charity. Plain English guidance on inspections, landlord duties and what to do about unsafe work.

Two details make the difference. Check that the registration was live on the date of the inspection, not just today. And when you ring to confirm the report, use the number on the register, not the number printed on the document you are trying to check.

If you think a report has been made up

Fabricated electrical reports are a real problem, and the people who suffer are the tenants living with work that was never done. If something does not add up, this is the order to work through.

  1. Ask the electrician named on it for the original, direct from them. A refusal, or a copy that differs from yours, tells you a lot.
  2. Look the registration number up on the register above and ring the electrician on the number the register gives.
  3. If they are scheme registered, report it to that scheme. Schemes have a complaints and technical route, can inspect the installation, and can act against a member.
  4. If they are not registered, or you believe the installation is unsafe, contact your local authority. For a rented home, the private housing or environmental health team enforces the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020. Building control handles Part P for notifiable work.
  5. If money changed hands for an inspection that did not happen, report it to Action Fraud, or to Police Scotland if you are in Scotland.
  6. If you think there is immediate danger, do not wait for any of the above. Get a registered electrician out to isolate and make safe.

Electrical Safety First publishes plain English guidance on all of this and is worth reading before you escalate.

Common questions

How can I tell if an EICR is genuine?

Check three things. First the document: a real Electrical Installation Condition Report names the person who inspected, the business they inspected for, a competent person scheme and registration number, and it carries a schedule of inspection, a schedule of test results with actual readings circuit by circuit, any observations with a classification code, an overall assessment, a date for the next inspection with a reason for the interval, and a signature. Second the person: search their registration number on their scheme register. Third, ring them, using the number on the register rather than the number printed on the report, and ask them to confirm they produced it.

Is there a national database where I can check an EICR?

No. There is no public UK register of Electrical Installation Condition Reports, and no way to look one up by address or by certificate number. A condition report is an inspection rather than notifiable work, so it is not notified to building control and no public register holds a copy of it. What is public is the register of scheme registered electricians, which is how you check the person rather than the paper.

Can I check a TradeBooked document by its number or the property address?

No, and that is on purpose. The only way in is the unguessable link the document carries in its own QR code. A search by certificate number or address would let anyone fish for other people's records, so there is no search box. If you do not have the document, ask the business that issued it to send it again.

Does a QR code mean a certificate has been verified as correct?

No. A QR code can only show you the record the issuing business created. It cannot check the readings, the observations, the overall assessment, or whether the person was competent to carry out the inspection. Read the word verified, on any platform including ours, as "this is the document that was issued", never as "this document is right".

Does an unsatisfactory EICR mean a property is unsafe to live in?

Not on its own, but it does mean something was found that needs work. Unsatisfactory means at least one observation was coded C1 (danger present) or C2 (potentially dangerous). A C1 needs immediate action, and a competent electrician should have made it safe on the day. For a private rented home in England the landlord must have the further investigation or remedial work completed within 28 days of the report, or sooner if the report says so, and obtain written confirmation.

How long is an EICR valid for?

An EICR does not expire the way an MOT does. It records the condition of an installation on the day it was inspected and recommends a date for the next inspection, and the inspector has to give a reason for the interval they chose. For a private rented home in England the maximum interval is five years. A change of occupancy, alterations to the installation, or damage can all mean the next inspection is due sooner. Requirements differ across England, Wales, Scotland and Northern Ireland.